Unit Control Menu

The Unit Control menu includes the following options:
Show
Reset Unit
Change Password
SW Versions Control
Configuration Control
Ethernet Port Operation Mode
Show
Select this option to view the current values/selected option of
applicable parameters as well as general status information, as follows:
SW Versions:
Main SW File Name
Main SW Version
Shadow SW File Name
Shadow SW Version
Running from: indicates whether the unit is running now the
Main or the Shadow version.
Upload/Download Parameters:
TFTP Server IP address: the IP address of the TFTP server used
for SW version download.
SW File Name: the name in the TFTP server of the SW version to
be downloaded to the unit.
Ethernet Port Operation Mode parameters and status
Current Eth Mode: the actual operation mode of the Ethernet
port.
Configured Eth Mode: the configured operation mode of the
Ethernet port.
Detected Eth Mode: the actual speed and duplex parameters of
the Ethernet port.