Installing the Micro Base Station Unit
The indoor equipment should be installed as close as possible to the
location where the IF cable(s) enters the building. The location of the
indoor equipment should take into account its connection to the power
source and to the base station networking equipment.
To install the Micro Base Station:
1. Place the unit on a shelf/desk or install it in a 19 inch cabinet. For
installation in a 21" cabinet, attach suitable ETSI rack adaptors to
the chassis.
2. Connect one end of a grounding cable to the grounding screw
located on the rear panel of the unit (marked ) and firmly tighten
the grounding screw. Connect the opposite end of the grounding
cable to a ground (earth) connection or to the cabinet, if applicable.
3. Connect the DATA port to the backbone data equipment (use a
straight Ethernet cable to connect to a hub/switch/router). The
maximum length of the Ethernet cable is 100m.
4. If the MGMT port will be used for remote management, connect the
it to the appropriate data equipment (use a straight Ethernet cable
to connect to a hub/switch/router). The maximum length of the
Ethernet cable is 100m.
5. For an AC model: Connect the power cord to the unit's AC socket,
located on the rear panel. Connect the other end of the power cord
to the AC mains. The unit can operate with AC mains of 100-240
VAC, 50-60 Hz.
NOTE
The color codes of the power cable are as follows:
Brown
Blue
Yellow/Green
For a DC model: Connect the power cord to the unit's DC socket,
located on the rear panel. Connect the other end of the power cord
to the -48 VDC power source.
6. Connect the IF cable (already connected at the other end to the
AU-ODU) to the ODU 1 connector. To avoid transmissions at
undesired frequencies, verify that the frequency and bandwidth
parameters are properly configured before connecting the IF cables.
Manual Revision 1.0
Installing the Micro Base Station Equipment
Phase
~
Neutral
0
Ground
2-35