Alvarion BreezeMAX 3500 System Manual page 146

Hide thumbs Also See for BreezeMAX 3500:
Table of Contents

Advertisement

Chapter 4 - Operation and Administration
BER Test
The BER Test sub-menu enables to initiate a BER test on the link with
a specific SU, including definition of test parameters, to terminate a test
and to view test results. It includes the following options:
Start Test
Stop Test
Show Test Parameters and Results
Start Test
Select this option to define the parameters for a Bit Error Rate test and
to initiate a test. The test will be initiated once all parameters have been
configured. The parameters are:
SU MAC Address
The BER test is performed on a link with a specific SU. This is the MAC
address of the applicable SU.
Number of Bytes
The number of BER test bytes to be transmitted. The available range is
from 1,000 to 100,000,000 Bytes.
Rate
The rates to be used for the BER test in the uplink and downlink. Refer
to Table 4-3 on page 4-41 for details on the available rates.
Burst Size (Bytes)
The burst size in bytes. The available range is from 500 to 4,000 Bytes.
Test Priority
The service priority of the BER test. Services with higher priority will not
be affected by the test. The available options are RT (Real time), NRT
(Non Real Time), and BE (Best Effort).
Stop Test
Select this option to terminate a currently running BER test.
4-46
BreezeMAX System Manual

Advertisement

Table of Contents
loading