Redundant Power Modules Of Argus Omnibus - Barco Argus X Terminal User Manual

Hide thumbs Also See for Argus X Terminal:
Table of Contents

Advertisement

5.2.2 Redundant power modules of Argus OmniBus

The O
B
with redundant, hot-plug power modules can be connected to two independent power nets. If one
MNI
US
of the two power modules or a power net is failing the LED D operating status [3] at the front changes from green
to red and starts blinking. This LED remains blinking as long as the failure persists, please refer to section
Argus
OmniBus. One of the possible reasons could be, that one power module has failed. Therefore proceed as
follows:
Open the ventilation flap as explained in section
Examine the power modules. They are located at the lower front of the O
1
securing screw
2
green LED: Output power good
3
handle
4
green LED: Input power good
5
air supply
Each power module has again two LED's to indicate the power state, the right LED Input power good [4] is
lightened if the connection to the power supply is OK. The left LED Output power good [2] is lightened, if the
output power of the module is OK. The table below lists the different LED status combinations and their meaning:
LED [4]
LED [2]
Input power
Output power
good
good
On
On
On
Off
Off
Off
If you detected that one power module must be exchanged then, switch off the power supply by means of
the respective power switch [26] on the back of the
LED Input power good [4] should then be off.
On the front loosen the securing screw [1] of the defective power module. You need an Allen key size 3/16"
to turn the screw. This Allen key was provided with the system. When the screw is loosened use the handle
[3] to remove the module.
Barco – Argus X Terminal – DOC-3265-2 – user's manual – Revision 04 – May-2004
5.2.1 Opening the front of the Argus
1
2
3
5
5
Meaning
There is power supplied to the power module and it is working well.
There is power supplied to the power module. The power module has a
failure and must be replaced.
There is no power supplied to the power module, e.g. the power net
failed or the power cable is not connected.
In rare cases it could be possible that there is a defect at the contacts of
the power module. Then it might help to exchange the power module.
6] on the back of the O
MNI
B
.
MNI
US
4
5
B
, please refer to section