Replacing A Fan Of The Argus Omnibus - Barco Argus X Terminal User Manual

Hide thumbs Also See for Argus X Terminal:
Table of Contents

Advertisement

5.2.4 Replacing a fan of the Argus OmniBus

If a fan is defective, it can be exchanged during operation of the A
below steps:
Open the front of the O
After removing the ventilation flap, have a look at the fans. They are still spinning, but the defective fan will
spin too slow or not at all.
Wait until all fans have stopped spinning!
Open the securing screws [1], [2] or [3] of the defective fan, please see
The fan is mechanically stuck to the housing and its power cord is plugged to the power supply. Therefore
first flap the fan slightly to the front and then lift it a little upwards to release it from the fitting. Then place it
in front of the housing in such a way that the cable is not tense, see the figure below:
1
jack of the housing
2
connector of the fan
On the connector of the cable there is a hook. Push this hook, this enables to unplug the connector [2].
Take a new fan and plug the connector into the jack.
Reattach the new fan in the fitting and turn it upwards. Take care that you do not clamp the cable between
fan and housing.
Tighten the securing screws of the fan [1], [2] or [3], which you loosened before.
Readjust the ventilation flap at the front of the O
Barco – Argus X Terminal – DOC-3265-2 – user's manual – Revision 04 – May-2004
B
as explained in section
MNI
US
O
RGUS
MNI
5.2.1 Opening the front of the Argus
Removing a fan (left) and detail of the cable connection (right)
(left) and detail of the cable connection (right)
B
and tighten the three screws at the upper side.
MNI
US
_________________________________________________________________________
5. Maintenance
B
. To exchange a fan follow the
US
OmniBus.
Figure 3-5 Front of the Argus
1
2
OmniBus.
Figure 5-6
5-8

Advertisement

Table of Contents