Barco Argus X Terminal User Manual page 45

Hide thumbs Also See for Argus X Terminal:
Table of Contents

Advertisement

Connecting order remote power on/off and genlock
In general all O
B
devices that are locked to the same source must be connected to each other by means of
MNI
US
the remote power on/off cabling.
Therefore in a distributed system an additional connection is necessary; the remote power on/off connector
[16] on the back of the central processor must be connected with external genlock loop through in connector
[15] on the back of the first rendering processor. The remote power on/off out connector of the last O
must be connected to the external genlock loop through in connector [15] on the back of the next rendering
processor.
If multiple A
systems shall be locked to the same source, the remote power on/off out connector of the
RGUS
last O
B
must be connected to the external genlock loop through in connector [15] on the back of the
MNI
US
central processor of the next A
If an external source is used for genlocking it must be connected to the external genlock in connector [17] on
the back of the A
P
RGUS
ROCESSOR
An example of cabling for an external genlock source is given in the figure below:
external
genlock
Central Processor
A
System 1
RGUS
Central Processor
A
System 2
RGUS
Barco – Argus X Terminal – DOC-3265-2 – user's manual – Revision 04 – May-2004
system.
RGUS
.
Rendering 1
Rendering 2
Rendering 1
Rendering 2
cabling for remote power on/off and external genlock
________________________________________________________________________
3. Getting started
B
MNI
US
Figure 3-36
3-27