3.3.2 Switching on
First make sure that the power switches [26] of all connected O
[3] on each O
B
should show a red light. Check also that the power switches [35] (if available) on the rear of
MNI
US
the A
P
and rendering processors are switched on. Then switch on the A
RGUS
ROCESSOR
dering processors by pressing the power button [13] on the front of each device! By means of the remote
power on/off mechanism each
/off mechanism each O
status of each O
B
should show a green light.
MNI
US
If the remote power on/off mechanism is not used, each O
push button on/off [4] on the front. If the LED of each of it turns green, the respective host can be switched on
as well.
The order in which the central processor and the rendering processors are switched on is of
no importance.
There are two possible boot modes for A
6.2.1 Boot
modes. The operation of A
Normal boot mode
The displays show their respective bus and slot no., e. g.:
PCI Bus: 2, PORT: 1
After a few minutes the graphical user interface X.11 appears.
eXtended safety boot mode
Xtended safety boot mode
The displays show their respective bus and slot no., e. g.:
PCI Bus: 2, PORT: 1
The A
startup screen comes up. Select linux to boot from the working partition.
RGUS
If you select backup, the restore procedure is started and the working partition becomes
overwritten with the backup system, which might lead to a loss of current data, depending
on the state of the backup, please see section
After a few minutes the graphical user interface X.11 appears.
Configuration
If software configuration has already been carried out you can go on with chapter
configuring A
in section
RGUS
Barco – Argus X Terminal – DOC-3265-2 – user's manual – Revision 04 – May-2004
B
is switched on and initialized in the necessary order. The LED operating
MNI
US
. Normal boot mode and eXtended safety boot mode. See section
RGUS
differs a little, depending on this mode.
RGUS
3.4 Configuration
software.
B
devices are on. The LED operating status
MNI
US
B
must be switched on first by means of the
MNI
US
Xtended safety boot mode. See section
4.8.5 Backup and restore procedures (eosxs Utility) )
4
Operating. Otherwise proceed
________________________________________________________________________
3. Getting started
P
and the ren-
RGUS
ROCESSOR
!
Figure 3-45
Argus startup screen
3-37