5.1 Hot plug procedure

5.1.1 Redundant power module

The redundant power modules of E
the two power modules or a power net is failing, you can hear a buzzer alarm that can be reset by pushing the
red buzzer reset button [5] / [2] at the front of E
Extender. Also the LED power module failed [6] / [4] at the front lightens up. This LED stays lightened as long as
the failure persists even if the buzzer reset button was pressed.
14
air supply
25
mains connection
35
power switch
36
green LED: power module operating
37
securing screw
38
handle
The defective power module or the failing power net can be located by examining the individual LED's power
module operating [36] on the back of E
it is switched on, the module is either defective and must be re-placed or the power net connected to it has
failed.