2. Setup setting at high altitude place.
When setup is done at high altitude place, execute as follows (such as in Mexico City). (see page 1-3-
83).
U140 -> AC Calib -> Calibration -> Execute -> Start
Result: developing leak image occur (see page 1-4-220).
U140 - AC Calib -> Lowering the numerical value of Magnification
3. Drum refresh (see the operation guide)
Press the System menu key.
Press [Adjustment/Maintenance] and then [Next] of [Drum Refresh].
Press [Execute] to perform drum refresh. When completed, press [OK].
Setting the maintenance item U952 (see page 1-3-199)
1. Enter the maintenance mode by entering 10871087 using the numeric keys.
2. Enter 952 using the numeric keys and press the start key.
3. Select [Execute].
4. Select [SETUP].
5. Press the start key.
*: Running the simulation allows execution histories to be logged.

Exit maintenance mode

1. Enter 001 using the numeric keys and press the start key. The machine exits the maintenance mode.

Completion of the machine installation

*: The maintenance mode U952 [SETUP] includes the following:
If U952 is not used, follow the procedure below.

Adjusting the image

1. Performing calibration
U464 Setting the ID correction operation - performing calibration (see page 1-3-175)
*: See the operation guide
Press [Adjustment/Maintenance] and then [Next] of [Calibration].
Press [Execute] to perform calibration. When completed, press [OK].
2. Adjusting the halftone automatically (see page 1-3-151)
Load the cassette with multiple sheets of A4 or Letter paper.