Setting The Main High Voltage - Kyocera FS-6525MFP Service Manual

Hide thumbs Also See for FS-6525MFP:
Table of Contents

Advertisement

Item No.
U100

Setting the main high voltage

Description
Performs main charging.
Purpose
To check main charging.
Method
1. Press the start key.
2. Select the item. The screen for executing each item is displayed.
Main charger
Laser
DC Bias
Idc Bias
Set Low Temp
Method:[Main charger/Laser]
1. Press the start key.
2. Select [Execute] and press the start key.The operation starts.
Setting: [DC Bias]
1. Select an item to be set.
2. Change the setting value using the cursor left/right keys or numeric keys.
Display
Full
Half
Adj Full
Adj Half
3. Press the start key. The value is set.
Display
Confirming of main motor driving and main charger operating
Confirming of laser operating
DC bias setting
Idc bias setting
Control setting of main charger (At the low temperature)
DC bias regulations value at the full speed
(Only the display)
DC bias regulations value at the half speed
(Only the display)
DC bias setting value at the full speed
DC bias setting value at the half speed
Description
Description
Description
1-3-39
2MW/2MX
Setting
Initial
range
setting
0 to 255
-
0 to 255
-
-500 to 500
0
-500 to 500
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-6530mfp

Table of Contents