TC35i AT Command Set
2.9 AT+CFUN
EXAMPLE 2
To set the ME to NON-CYCLIC SLEEP mode enter
AT+CFUN=0
OK
When, for example, an SMS is being received and indicated by an unsolicited result code (URC), the ME
wakes up to full operation.
+CMTI: "SM",5
Note that the URC used in this example will appear only, if
After this, you may want to verify the operating status:
AT+CFUN?
+CFUN: 1
EXAMPLE 3
To stop CYCLIC SLEEP mode and return to full functionality:
AT+CFUN?
+CFUN: 5
OK
AT+CFUN=1
OK
Remember that this approach is not applicable to the NON-CYCLIC SLEEP mode (since the serial interface
is disabled). The NON-CYCLIC SLEEP mode ends with the first wake-up event.
EXAMPLE 4
To reset and restart the ME:
AT+CFUN=1,1
OK
^SYSSTART
2.9.1

Wake up the ME from SLEEP mode

A wake-up event is any event that switches off the SLEEP mode and causes the ME to return to full functionality.
In short, it takes the ME back to
Definitions of the state transitions described in the table below:
Yes means: ME exits SLEEP mode
No means: ME does not exit SLEEP mode
Event
Ignition line
/RTS0
TC35i_ATC_V02.07
Confidential / Released
Indicates that ME has entered full functionality mode.
or alternatively, AT+CFUN=0,1 or 5,1 or 6,1 or 7,1 or 8,1
The ^SYSSTART URC confirms that the ME has been rebooted. Note
that ^SYSSTART appears only if
mode, it is recommended to wait 3 to 5 seconds before entering the first
AT command. Remember to enter the SIM PIN after restart.
=1.
AT+CFUN
From
=0 to
<fun>
=1
<fun>
No
Yes
Page 42 of 439
=1,1 was configured before.
AT+CNMI
AT+IPR
From
=5 or 6 to
<fun>
=1
<fun>
No
No
s
m
obile
¹ 0. If the ME is in autobaud
From
=7 or 8 to
<fun>
=1
<fun>
No
No
1/30/04