18.2.4. X 203) CAN Bus Port
If a termination resistor (120Ω) is required, you have to make a connection (bridge)
between pin 1 and 2, respectively pin 7 and 8, in order to enable the onboard termination
resistor (120Ω).
Table 50: CAN Bus Port
Pin
Signal Name
1
TERM L
2
CAN_L
3
CAN_GND
4
NC
5
NC
6
NC
7
CAN_H
8
TERM H
9
NC
www.kontron.com
120Ω
CAN_L bus line (dominant low)
(CAN Ground) Reference potential
(not connected)
(not connected)
(not connected)
CAN_H bus line (dominant high)
120Ω
(not connected)
KBox C-102 - User Guide, Rev. 1.0
9-pin D-SUB Connector
(male)