10.4. Cleaning the Air Filter

The air filter is inserted in the holder (Figure 31, pos. 2) at the bottom side of the fan tray slot (Figure 31, pos. 6). The
soiling of the air filter (Figure 31, pos. 3) is caused by the pollution of the operating environment. A heavily soiled air
filter can cause excessive heating of the device. For this reason we recommend to clean the air filter as often as
necessary. The air filter can be changed during operation of the system.

Figure 52: Fan tray extension (detail: shown as KBox C-102-1)

1
3
2
2
1
3
To replace the air filter, proceed as follows:
1.
Ensure to have access to the bottom side of the KBox C-102-4/-2/-1. The air filter may be replaced without
removing the fan tray (Figure 52, pos. 1).
2.
Loosen the knurled screw (Figure 52, pos. 3) that secures the air filter holder (Figure 52, pos. 4) to the fan tray
slot (Figure 52, pos. 5); refer to step 1 in Figure 52.
3.
Pull the air filter holder out of the positioning holes, (Figure 53, pos. 9) into the marked direction (see Figure 52)
and pull it down. Put the air filter holder aside for later reassembly; refer to step 2 and 3 in Figure 52.
4.
Remove the soiled air filter (Figure 52, pos. 3 and Figure 53, pos. 6).
5.
Clean the air filter as follows:
6.
Rinse in water (up to approx. 40°C; possibly with the addition of a standard mild detergent).
7.
It is possible to clean the air filter with compressed air.
8.
For dirt that contains grease/oil, the air filter should be rinsed with warm water with the addition of a degreaser.
Air filter should not be cleaned with powerful water jets or wrung out.
9.
After cleaning and drying the air filter, place it in the air filter holder.
10. Reattach the air filter holder to the bottom side of the fan tray slot by inserting the positioning latches
(Figure 53, pos. 8) into the positioning holes (Figure 53, pos. 9).
11. Secure the air filter holder by tightening the knurled screw to the tapped hole (Figure 53, pos. 4) of the fan tray
slot
(Figure 52, pos. 5 or Figure 53, pos. 3).
Defective components may only be replaced by Kontron original spare parts.
www.kontron.com
4
2
Air filter: part number: 9-5000-1099 (for KBox C-102-4)
Air filter: part number: 9-5000-1098 (for KBox C-102-2)
Air filter: part number: 9-5000-1097 (for KBox C-102-1)
5
KBox C-102 - User Guide, Rev. 1.0
1
Fan tray
2 Knurled screws of the fan tray
3 Knurled screw of the air filter
holder
4 Air filter holder
5 Fan tray slot
// 65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kbox c-102-2Kbox c-102-1Kbox c-102-4Kbox c-102-0

Table of Contents