7.9 Operating conditions

Torques
Table 7-24
Description
Plastic blind plugs
Plastic cable glands
Brass cable glands/blind plugs
Stainless steel cable glands/blind
plugs
Table 7-25
Description
Enclosure lid screws
Pipe mounting nuts
Table 7-26
Description
Wall bracket screws
Transmitter to wall bracket
Transmitter pedestal lock screw
Pedestal lock screw cap
Note
NPT glands on wall mount enclosure
When using NPT glands, the user must take care to use the supplied NPT thread adaptors.
7.9
Operating conditions
Table 7-27
Description
Ambient temperature
(Humidity max. 90 %)
Ambient temperature
(Humidity max. 90 %)
Climate class
Altitude
Pollution wall mount enclosure
102
Cable gland to enclosure installation torques (Siemens supplied, metric)
Torque (Nm)
1.2
4.5
10
11
Wall mount enclosure installation torques
Torque (Nm)
6
10
Industrial enclosure installation torques
Torque (Nm)
10
25
10
10
Basic conditions
Operation:
Transmitter without display
Display
Storage:
Specification
-40 to +60 °C (-40 to +140 °F)
-20 to +60 °C (-4 to +140 °F)
-40 to +70 °C (-40 to +158 °F)
DIN 60721-3-4
Up to 2000 m (6560 ft)
Degree 2