Technical Data; General Technical Data - Edwards iXH100 Instruction Manual

Dry pumping systems
Table of Contents

Advertisement

2

Technical data

2.1

General technical data

Body dimensions
Length x Width x
Pump
Height
(excludes exhaust
*
enclosure)
Units
mm
iXH100
784 x 390 x 526
iXH200H
901 x 390 x 526
iXH450H
1000 x 517 x 650
iXH500H
1000 x 517 x 650
iXH610
784 x 390 x 780
iXH1210/H
784 x 390 x 780
iXH1220H/T
901 x 390 x 780
iXH1820/H/T
901 x 390 x 780
iXH3030/T
915 x 517 x 966
iXH3045H
1000 x 517 x 966
iXH3050H
1000 x 517 x 966
iXH4545HT
1000 x 517 x 966
iXH4550HT
1000 x 517 x 966
iXH6045H/T
1080 x 517 x 966
iXH6050H/T
1080 x 517 x 966
pXH4500
1086 x 517 x 531
pXH6000
1086 x 517 x 531
iXL250Q
1092 x 390 x 830
iXL500Q
1186 x 517 x 966
iXL500R
1186 x 517 x 966
Table 1 - General technical data
Mass
Typical
Noise level
(excluding
vibration
(at ultimate)
packaging)
level at inlet
kg
dB(A)
mm/s
260
< 70
< 1.5
287
< 70
< 1.5
455
< 70
< 1.5
490
< 70
< 1.5
355
< 70
< 1.5
413 - 430
< 70
< 1.5
455 - 460
< 70
< 1.5
471 - 487
< 70
< 1.5
619 - 624
< 70
< 1.5
776
70
< 1.5
811
70
< 1.5
814
70
< 1.5
849
70
< 1.5
860 - 865
74
< 1.5
899
70
< 1.5
400
< 70
< 1.5
435
< 70
< 1.5
515
<64
<1.5
860
< 70
< 1.5
874
< 70
< 1.5
Characteristics
Initial force
Sustained
Pump inlet
to push the
force to push
pump
the pump
kg force
kg force
< 20
< 4
< 20
< 4
< 20
< 10
< 20
< 10
< 20
< 4
< 20
< 4
< 20
< 4
< 20
< 4
< 20
< 10
< 20
< 10
< 20
< 10
< 20
< 10
< 20
< 10
< 20
< 10
< 20
< 10
< 20
< 10
< 20
< 10
<20
<10
< 20
< 10
< 20
< 10
Extraction
Exhaust gas
flange
port
outlet
(bolted)
diameter
mm
ISO63
NW40
105
ISO63
NW40
105
ISO63
NW40
105
ISO63
NW40
105
ISO100
NW40
105
ISO100
NW40
105
ISO100
NW40
105
ISO160
NW40
105
ISO160
NW40
105
ISO160
NW40
105
ISO160
NW40
105
ISO200
NW40
105
ISO200
NW40
105
ISO250
NW40
105
ISO250
NW40
105
ISO200
ISO160
-
ISO250
ISO160
-
ISO160
NW40
105
ISO160
NW50
105
ISO160
NW50
105

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents