Edwards iXH100 Instruction Manual page 24

Dry pumping systems
Table of Contents

Advertisement

Characteristics
iXH3030/T
Dry pump motor rating
7.5
Mechanical booster
7.5
motor rating
Current rating
44
(200 - 230 V systems)
Current rating
23
(380 - 460 V systems)
Recommended branch
55
circuit fuse UL
(200 - 230 V systems)
Recommended branch
45
circuit fuse IEC
(200 - 230 V systems)
Recommended branch
30
circuit fuse UL
(380 - 460 V systems)
Recommended branch
25
circuit fuse IEC
(380 - 460 V systems)
Min cable size for 200 -
10 (6)
230 V systems (or
corresponding AWG
size)
*
Min cable size for 380 -
6 (8)
460 V systems (or
corresponding AWG
size)
®
Mains connector
Han
K 4/4
*
The minimum geometric wire gauge for Han® K 4/4 is 6mm² and minimum AWG size is 8 AWG
The minimum geometric wire gauge for Han® 100A module is 10mm² and minimum AWG size is 6 AWG
Table 7 - Electrical data iXH3030/T to pXH6000 (continued)
iXH3045H
iXH3050H
iXH4545HT
11
11
11
7.5
7.5
7.5
63
63
63
32
32
32
80
80
80
65
65
65
40
40
40
35
35
35
25 (4)
25 (4)
25 (4)
10 (6)
10 (6)
10 (6)
®
®
®
Han
100 A
Han
100 A
Han
100 A
module
module
module
iXH4550HT iXH6045H/T iXH6050H/T
11
11
11
7.5
7.5
7.5
63
63
63
32
32
32
80
80
80
65
65
65
40
40
40
35
35
35
25 (4)
25 (4)
25 (4)
10 (6)
10 (6)
10 (6)
®
®
®
Han
100 A
Han
100A
Han
100A
module
module
module
pXH4500
pXH6000
Units
-
-
kW
7.5
7.5
kW
28
28
A
14
14
A
35
35
A
30
30
A
20
20
A
15
15
A
*
*
2
6 (8)
6 (8)
mm
(AWG)
*
*
2
6 (8)
6 (8)
mm
(AWG)
®
®
Han
K 4/4
Han
K 4/4
-