Electrical Connections - Edwards iXH100 Instruction Manual

Dry pumping systems
Table of Contents

Advertisement

Description
Mains connection
Refer to installation section for wiring diagram
PDT Interface (front)
System Interface (rear)
Ethernet interface
EMS interface
External emergency stop switch
Pin 1 - supply, Pin 2 - return
Note: If there is no external connection a link
plug must be fitted to operate the pump.
Internal emergency stop switch
Pin 3 - common, Pin 4 - normally open
Comms 24 V supply
Pin 5 - supply, Pin 6 - 0 V supply common
Chassis
Table 9 - Electrical connections
Mating Connector description / external supply rating
Refer to
Table 7
for the mains connector fitted to each variant.
Connector is either:
Harting Han® K 4/4-F finger safe
09 38 008 2703, 6-16 mm
(VDE 0295 class 5, refer to
Table
Harting Han® Axial Screw module 100A (2 off required), 09 14 002 2753 10-25 mm
or 09 14 002 2751, 16-35 mm
(VDE 0295 class 5, refer to
Harting Han® Axial Screw module 200A (3 off required), part number of mating
2
half suitable for 25 - 40 mm
wire is 09 14 001 2763 or 09 14 001 2762 for
2
40 - 70 mm
wire. Use fine stranded wire (VDE 0295 class 5, refer to
XLR type 5-way plug
XLR type 5-way plug
Standard RJ45 type or Neutrik® EtherCon® RJ45
XLR type 6-way plug
30 V a.c. 1 A, 60 V d.c. 0.55 A
2
fine stranded wire
10), 8.9mm max insulation diameter
Or
2
fine stranded wire
Table
10)
Or
Table
Internal supply rating
2
10)
24 V d.c. 0.2 A
*
24 V d.c. 0.75 A
(IEEE802.3i
10 Base T Ethernet)
24 V d.c. 100 mA
*
24 V d.c. 0.75 A