4.4

Automatic shut-down

If you select 'Run 'til crash', the pump(s) can be damaged and you may invalidate any warranties on the system
equipment.
Normally, if an alarm condition exists, the control system will shut down the dry pumping system. For pumping
systems containing a dry pump and booster combination, some alarms will cause only the booster to stop, and not
the full system.
Notes:
1. If required you can request 'Run 'til crash' operation. In this mode of operation, most alarm conditions
will be ignored and the pump(s) will continue to operate. For safety reasons, some alarms cannot be
overridden and the system will automatically shut down even if you have selected 'Run 'til crash'.
Refer to
Table
2. 'Run 'til crash' is automatically reset to 'off ' when the electrical supply is removed.
3. The Tool Interface overrides the 'Run 'til crash' state selected provided it has control of the pump.
Alarm Description
EMS or System Configuration (set-up) fault
*
Exhaust Pressure
Booster Stator or End Cover Temperature
Dry Pump Stator or End Cover Temperature
Booster status
*
Dry Pump status
*
Not applicable to pXH systems.
Not applicable to systems which do not contain a booster.
Page 42
CAUTION
19.
Table 19 - Alarm actions
Alarm stops dry
*
Edwards and the Edwards logo are trademarks of Edwards Limited.
Alarm stops booster
pump
pump
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
No
Yes
Yes
Yes
© Edwards Limited 2012. All rights reserved.
Alarm overrides
'Run 'til crash'
Yes
Yes
No
No
Yes
Yes