M561-00-880 Issue C
Warning Message
'Action' Message on
on PDT
PDT
Warning 39.11
Exhaust Blocked
Exh Press High
Service Pump
Warning 39.13
-
Sensor missing
Warning 51.13
See manual
Sup Missing
Warning 54.11
See manual
MB Temp High
Warning 54.13
-
Sensor missing
Warning 55.13
-
Sensor missing
Warning 57.11
See manual
DP E/C Temp High
Warning 57.13
-
Sensor missing
Warning 62.11
See manual
MB E/C Temp High
Warning 62.13
-
Sensor missing
Warning 63.11
See manual
DP Temp High
Warning 63.13
-
Sensor missing
Warning 70.11
See manual
DP Temp 2 High
Page 66
Table A15 - Warnings (continued)
Possible Cause
The pressure in the exhaust pipeline is too
high.
- A valve in the pipeline may be shut.
- There may be process debris or
condensation in the exhaust pipeline.
-You may have too many pumping systems
connected to the exhaust pipeline.
The exhaust pressure transducer is not
fitted, or is disconnected or has failed.
There is a communication problem within
the pump controller. Refer to
Section A2.4.1
for more information.
The temperature of the booster pump is
too high.
The booster temperature sensor may have
become disconnected or failed.
The dry pump temperature sensor may
have become disconnected or failed.
The temperature of the dry pump end
cover is too high.
The dry pump end cover temperature
sensor may have become disconnected or
failed.
The temperature of the booster end cover
is too high.
The booster end cover temperature sensor
may have become disconnected or failed.
The internal temperature of the pump is
too high.
The dry pump temperature sensor may
have become disconnected or failed.
The temperature of the pump is too high.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Action
Refer to
Section 4.5
determine the exhaust
pressure that triggered the
warning.
Check that all valves in the
exhaust line are open and
consider whether process
debris or condensation are
likely.
Contact Edwards.
Cycle the power to the
pump. If the warning
persists, contact Edwards to
replace the pump
controller.
- Check that cooling water is
connected, switched on and
is to specification given in
Section
2.6.
- Check that the sensor is
fitted and is correctly
connected.
- Check that the sensor is
fitted and is correctly
connected.
- Check that cooling water is
connected, switched on and
is to specification given in
Section
2.6.
- Check that the sensor is
fitted and is correctly
connected.
- Check that cooling water is
connected, switched on and
is to specification given in
Section
2.6.
- Check that the sensor is
fitted and is correctly
connected.
- Check that cooling water is
connected, switched on and
is to specification given in
Section
2.6.
Contact Edwards.
- Check that cooling water is
connected, switched on and
is to specification given in
Section
2.6.