Appendix A2
A2.1

Warnings

The pump controller generates a warning when a problem is encountered. Once the problem that caused a warning
has been resolved, the warning is cleared by the pump controller.
A2.1.1
LED warning indicators
If the pump encounters a problem, warnings are indicated on the LEDs on the front control panel, the rear panel and
on the PDT if fitted.
The warning LEDs on the front control panel and rear panel illuminate continuously when a warning is generated.
If a PDT is fitted, the warning LED flashes to indicate a new warning. Refer to
on how warnings are indicated and how they can be acknowledged using the PDT.
Once all the warnings are cleared, the warning LEDs extinguish.
A2.1.2
PDT warnings
If a PDT is fitted, each warning triggers a warning message to be displayed. Refer to
information on how warnings are handled by the PDT.
Table A15
lists the warning messages that might be displayed on the PDT with possible causes and actions you should
take.
Warning Message
'Action' Message on
on PDT
PDT
Warning 1.01
Check pwr supply
Power interrupt
Warning 31.13
See manual
Gas missing
Warning 31.01
See manual
SYS CONFIG FAULT
Warning 35.10
Check N2 supply
N2 Purge Low
Warning 35.11
Check Gas Module
N2 Purge High
Warning 35.13
-
Sensor missing
© Edwards Limited 2012. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Troubleshooting
Table A15 - Warnings
Possible Cause
There has been a brownout of the
electrical supply to the pump lasting more
than 1 second.
The gas module is not communicating with
the pump controller.
The wrong type of gas module has been
fitted.
The Nitrogen supply flow rate is too low
- the supply might not be connected or
switched on
- the supply line or filter may be blocked
The Nitrogen supply flow rate is too high
- the gas module and PDT settings do not
match (for iXH Single Mode or Single
Mode+)
- the gas module may be faulty
The transducer is disconnected or has
failed.
M561-00-880 Issue C
Appendix A1.3
for more information
Appendix A1.3
for more
Action
Check the electrical supply
Contact Edwards.
Contact Edwards.
Check the Nitrogen supply is
connected and switched on
and that pipelines and
filters are not blocked.
Check the gas module and
PDT settings, refer to
Section
5.6.
Contact Edwards.
Contact Edwards.
Page 65