Operating Guide | VLT® Soft Starter MCD 600
Parameter group number
2-3
2-4
2-5
2-6
2-7
2-8
2-9
2-10
2-11
2-12
2-13
2-14
2-15
2-16
2-17
2-18
3
3-1
3-2
3-3
3-4
3-5
3-6
3-7
3-8
3-9
3-10
3-11
3-12
3-13
3-14
3-15
3-16
3-17
3-18
Danfoss A/S © 2018.10
Parameter group name
Initial Current
Current Limit
Adaptive Start Profile
Kickstart Time
Kickstart Level
Jog Torque
Stop Mode
Stop Time
Adaptive Stop Profile
Adaptive Control Gain
Multi Pump
Start Delay
DC Brake Torque
DC Brake Time
Brake Current Limit
Soft Brake Delay
Motor Start/Stop 2
Motor Full Load Current-2
Motor kW-2
Start Mode-2
Start Ramp Time-2
Initial Current-2
Current Limit-2
Adaptive Start Profile-2
Kickstart Time-2
Kickstart Level-2
Jog Torque-2
Stop Mode-2
Stop Time-2
Adaptive Stop Profile-2
Adaptive Control Gain-2
Multi Pump-2
Start Delay-2
DC Brake Torque-2
DC Brake Time-2
Programmable Parameters
Default setting
200%
350%
Constant Acceleration
000 ms
500%
50%
TVR Soft Stop
00:00 (mm:ss)
Constant Deceleration
75%
Single Pump
00:00 (mm:ss)
20%
00:01 (mm:ss)
250%
400 ms
Model dependent
0 kW
Constant Current
00:10 (mm:ss)
200%
350%
Constant Acceleration
000 ms
500%
50%
TVR Soft Stop
00:00 (mm:ss)
Constant Deceleration
75%
Single Pump
00:00 (mm:ss)
20%
00:01 (mm:ss)
AQ262141844215en-000202 / 175R1174 | 71