Emergency mode can be used with any command source. N O T I C E Although emergency mode operation satisfies the functionality requirements of fire mode, Danfoss does not recommend its use in situations that require testing and/or compliance with specific standards as it is not certified.
Page 123
Internal fault (PCB fault). The output from the current transformer circuit is not close enough to 0 when the SCRs are turned off. Troubleshooting • Contact the local Danfoss supplier for advice. • There are no related parameters to this trip message.
Page 126
11.2.21 Internal Fault X (Where X is a number) Cause The soft starter has tripped on an internal fault. Troubleshooting • Contact Danfoss with the fault code (X). 11.2.22 Internal Fault 88 Cause The soft starter firmware does not match the hardware. 11.2.23 LCP Disconnected Cause Parameter 1-1 Command Source is set to Remote LCP, but the soft starter cannot detect a remote LCP.
VLT® Soft Starter MCD 600 Operating Guide Troubleshooting Troubleshooting • Contact the local Danfoss supplier for advice. • There are no parameters relatedto this trip message. 11.2.55 Zero Speed Detect Cause The zero-speed detect input has not closed within the expected duration of a soft stop.
Page 140
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.