Siemens TC35i User Manual page 396

Terminal hardware interface
Hide thumbs Also See for TC35i:
Table of Contents

Advertisement

TC35i AT Command Set
16.1 AT+CALA
Unsolicited Result Codes
URC 1
+CALA:
<text>
Indicates reminder message.
URC 2
^SYSSTART ALARM MODE
+CALA:
<text>
Indicates ME wake-up into Alarm mode. If autobauding is active (
MODE" does not appear, but your individual
Command Description
Test command returns supported array index values
to be output.
<tlength>
Read command returns the list of current alarm settings in the ME.
The write command sets an alarm time in the ME. When the alarm is timed out and executed the ME returns an
Unsolicited Result Code (URC) and the alarm time is reset to "00/01/01,00:00:00".
The alarm can adopt two functions, depending on whether or not you switch the GSM engine off after setting the
alarm:
Reminder message: You can use the alarm function to generate reminder messages. For this purpose, set
the alarm as described below and do not switch off or power down the ME. When executed the message
comes as an Unsolicited Result Code.
Alarm mode: You can use the alarm function to restart the ME when powered down. For this purpose, set the
alarm as described below. Then power down the ME by entering the
time is reached, the ME will wake up to Alarm mode. To prevent the ME from unintentionally logging into the
GSM network, Alarm mode provides restricted operation. Upon wake-up, the ME indicates an Unsolicited
Result Code which reads: ^SYSSTART ALARM MODE. A limited number of AT commands is available dur-
ing Alarm mode:
AT+CCLK
The ME remains deregistered from the GSM network. If you want the ME to return to full operation (normal
operating mode) it is necessary to drive the ignition line (IGT pin of application interface) to ground. If your
ME is battery powered note that the battery can be charged while the ME stays in Alarm mode. For details
please refer to [2].
Parameter Description
(str)
<time>
Format is "yy/MM/dd,hh:mm:ss", where characters indicate year (two last digits), month, day, hour, minutes. E.g.
6th of May 2004, 22:10:00 hours equals to "04/05/06,22:10:00" (see also
current date and time or is set to an earlier date, TA returns +CME ERROR: 21.
(num)
<n>
Integer type value indicating the array index of the alarm.
The ME allows to set only one alarm at a time. Therefore, the list of supported alarm events indicated by the test
command
=? is
AT+CALA
read command
AT+CALA
ious Multiplexer channels, for details see notes below.
TC35i_ATC_V02.07
Confidential / Released
<text>
,
,
,
AT+CALA
AT^SBC
=0. If a second alarm time is set, the previous alarm will be deleted. Therefore, the
<n>
? will always return
=0. This is also true if individual settings are made on the var-
<n>
Page 396 of 439
AT+IPR
message will be displayed.
, alarm types
<n>
<type>
AT^SMSO
,
.
AT^SCTM
AT^SMSO
AT+CCLK
s
m
=0) the line "^SYSSTART ALARM
, and maximum length of the text
command. When the alarm
). Note: if
<time>
obile
equals
1/30/04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc35i terminal

Table of Contents