Defining the serial line communication parameters for the PI50
and PI60 Receiver Units
The communication between the PI50 and PI60 Receiver Units and the Processor Unit
is made using a (1:1) serial line. All serial line communication is based on specific
transmission parameters. These parameters must be defined at each end of the line, and they
must be set up identical.
Prerequisites
The Receiver Unit is physically connected to the Processor Unit using a serial cable.
Procedure
1
Open the
Setup
2
On the
menu, select
Setup
Observe that the
3
Observe the
I/O Setup
Every interface is presented as a small "block diagram".
4
In the relevant block diagram, select the serial port icon.
Observe that the
5
Make the necessary adjustments.
The communication parameters defined for the PI50 and PI60 Receiver Units are:
: 4800 b/s
Baud rate
: 8
Data bits
: None
Parity
: 1
Stop bits
6
Select
to save the chosen settings and close the dialog box.
OK