25 Machine Parameter List
25.1 Excerpt from the iTNC 530 Technical Manual
25.1.1 Encoders and machines
MP
MP10
MP20
MP20.0
MP20.1
MP20.2
MP21
MP21.0
MP21.1
MP21.2
MP100
MP100.0
MP100.1
MP100.2
MP110.x
July 2002
Function and input
Active axes
Format: %xxxxxxxxxxxxxx
Input: Bits 0 to 13 correspond to axes 1 to 14
0: Axis not active
1: Axis active
Monitoring functions for the axes
Format:%xxxxxxxxxxxxxx
Input:Bits 0 to 13 correspond to axes 1 to 14
0: Monitoring not active
1: Monitoring active
Absolute position of the distance-coded reference marks
Amplitude of encoder signals
Edge separation of encoder signals
Monitoring functions for the spindle
Format: %xx
Input: Bit 0 – Spindle 1
0: Monitoring not active
1: Monitoring active
Bit 1 – Spindle 2
0: Monitoring not active
1: Monitoring active
No function
Amplitude of encoder signals
Edge separation of encoder signals
Designation of axes
Format: XYZABCUVWxyzabcuvw-
Input: Characters 1 to 9 correspond to axes 1 to 9
Traverse range 1
Traverse range 2
Traverse range 3
Assignment of position encoder inputs to the axes
Input:
0: No position encoder input
1 to 6: Position encoder inputs X1 to X6
35 to 38: Position encoder inputs X35 to X38
Software
version and
behavior
PLC
RUN
PLC
RUN
PLC
RUN
RESET
25 – 301