HEIDENHAIN iTNC 530 Service Manual page 46

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

Error message
Internet address
error
Missing calibration
data
No fixed cycle
defined
Nothing is marked
No appropriate tool
found
No sign permitted
No material
selected
Range cycle not yet
defined
No .TAB file open?
No axis column
selected
No editing of
running program
No drive release
%.2s
No rotary axis was
programmed
2 – 44
Error
Cause of error
number
2993
When the service support ON/OFF
soft key was pressed there was no
valid Internet address entered
under the code word
SERVICE.REQUEST.HOST or
SUPPORT.REQUEST.HOST in the
OEM.SYS file.
3192
You have attempted to perform a
measurement with Cycle 440
without first performing a
calibration.
1855
There is no fixed cycle defined
before Cycle 220/221 (circular/linear
point pattern).
2665
You attempted to fill the
intermediate memory using the
DELETE BLOCK, COPY BLOCK soft
keys, although you have not yet
marked a block.
3181
Automatic tool search: The TNC
could not find an appropriate tool in
the tool table.
1812
You attempted to enter an algebraic
sign in a cycle parameter for which
a sign is not permitted.
2228
You attempted to have the TNC
automatically calculate the spindle
speed or the feed rate without first
selecting a workpiece material in
the workpiece blank definition.
1797
There was no range cycle defined
before the start of a digitizing cycle.
2736
You attempted to use FN27 to write
to a table, or FN28 to read from a
table, although no table was open.
2734
While editing a pallet table, you
pressed the actual-position-capture
key and the PRESENT VALUE soft
key, although the highlight was not
on an axis column.
949
You cannot edit the program while
it is being transferred or executed.
2994
Inverter is not ready for operation.
No pulse release for the power
supply unit.
Uz too high.
Power-fail signal is active.
If M control: NE2 input is active.
If P control: drive release at X50 is
inactive.
Motor control board defective.
PWM cable defective.
Noise pulses.
337
The axis recognized as main axis in
Cycle 27 (Cylinder Surface, ISO:
G127) is not a rotary axis.
Corrective action
Check with the machine
manufacturer about the Internet
address.
Repeat Cycle 440, but with
Q363 = 0 (calibrate).
Define a fixed cycle before Cycle
220/221.
Mark the block that you wish to
delete/copy.
Check the tool table.
Press CE to acknowledge the error
message.
Enter the workpiece material in the
workpiece blank definition.
Program the Range cycle before
the Digitizing cycle.
Use FN26 to open the desired
table.
Use the rightward/leftward cursor
keys to select the desired axis
column.
Stop the program or edit it after it
is finished.
Inform your service agency.
Check the control and cabling of
the pulse release.
Check Uz.
Check the emergency stop circuit.
If the power supply is not
regenerative: Is the braking resistor
connected?
If the power supply is regenerative:
Is the energy recovery activated?
Exchange the power module.
For P controls: Exchange the
interface card.
Exchange the motor drive control
board.
Edit the contour subprogram.