11.2 Checking the BC 150 Visual Display Unit

Fault diagnosis
If the machine is switched on, but the screen remains black:
Is the fan running?
Check the 24 V voltage at the 2-pin connector of the visual display unit.
If another BF 150 is available:
Test the VDU output X19 with this monitor.
If you have a dimensionally identical control:
Test the BF 150 with this control.
11 – 200
Note
If the power supply is in order, then a further inspection of the flat-panel display is not
possible without special test equipment.
Note
If required you can display the control monitor by means of the programs TNCremo,
TNCremoNT or TeleService.