Error message
Oriented spindle
stop inactive
Oscilloscope error
%1s
'PALETT' in
NCMACRO.SYS
missing
Wrong pallet
Pallet data missing
Pallet line locked
Parallel operation
not possible
Parallel operation
not possible
Parallel operation
not possible
Parallel operation
not possible
Mandatory field
deleted!
PGM %.16s is
missing
PGM CALL not
permitted
PGM not found
2 – 56
Error
Cause of error
number
165
You attempted to call either the
Rigid Tapping cyle or the Tapping
cycle, although your machine does
not have a controlled analog
spindle.
2904
Internal software error.
2102
Pallet changer: A pallet change was
started although there is no
NCMACRO.SYS file.
2100
Pallet changer: The part program
that was started belongs to another
pallet.
2103
Pallet changer: You started a part
program that does not belong to
any pallet.
3025
You attempted to run a locked
pallet line.
208
You attempted to start a program at
the same time in the Program Run
and Program Test operating modes,
or to start a program in the Program
Test mode during execution of a
PLC positioning command.
209
You edited the machine or user
parameter list and tried to exit the
editor with END. This is not
permitted if the part program or
a PLC positioning operation is
running.
210
You attempted to compile an FK
program or generate an FK graphic
simulation during a running NC
program or PLC positioning
operation.
2284
The window for the help text could
not be displayed. It could be that a
help window is already open in
another operating mode.
2385
While editing the structure of a
freely definable table you deleted
an element that is always required
by the TNC (mandatory element).
206
The program that you have selected
contains a program call into a
program that does not exist in
TNC memory.
270
A program call (PGM CALL, ISO:
%..) has been programmed in a
program being run blockwise from
an external data medium.
207
During execution of a blockwise
transferred part program (DNC
mode) the control found that a
called subprogram does not exist
in NC memory.
Corrective action
Contact your machine tool builder.
Inform your service agency.
Check software version.
Inform your service agency.
Change to the proper pallet.
Add the PALLET entry to the pallet
file. The PALLET entry assigns a
pallet to the part program.
To resume program run, unlock the
line or continue with the next line. If
necessary, refer to your machine
manual.
Start the part program only in one
of the operating modes.
Wait until the part program run is
ended, or interrupt it.
Stop the part program.
Close the window that is open
in parallel.
Reinsert the mandatory element.
If necessary, modify the program
name.
Modify the program call so than
the TNC can call an externally
stored program.
Delete the program call.
Load the part program.