MP
MP7237
MP7237.0
MP7237.1
MP7237.2
MP7238.0-7
MP7245
MP7246
MP7251
MP7260
MP7261.0-3
MP7262
MP7263
July 2002
Function and input
Displaying and resetting the operating times
Display PLC operating times
Input:
Bits 0 to 7 represent PLC operating times 1 to 8
0: Do not display
1: Display
Resetting PLC operating times with the code number
857282
Input:
Bits 0 to 7 represent PLC operating times 1 to 8
0: Do not reset
1: Reset
Resetting NC operating times with the code number
857282
Input:
Bit 0 – No function
Bit 1 – "Machine on" operating time
Bit 2 – "Program run" operating time
0: Do not reset
1: Reset
Dialog messages for PLC operating times 1 to 8
Input:
0 to 4095
Dialog no. from the file (OEM.SYS)
Disabling auxiliary cycles
Input:
0: Auxiliary cycles disabled
1: Auxiliary cycles permitted
Disabling paraxial positioning blocks
Input:
0: Paraxial positioning block enabled
1: Paraxial positioning block disabled
Number of global Q parameters that are transferred from
the OEM cycle to the calling program
Input:
0 to 100
Number of tools in the tool table
Input:
0 to 30,000
Number of pockets in the tool magazine 1 to 4
Input:
0 to 254
Maximum tool index number for indexed tools
Input:
0 to 9
Hiding/showing the POCKET TABLE soft key
Format:
%x
Input:
Bit 0 –
0: POCKET TABLE soft key is shown
1: POCKET TABLE soft key is hidden