MP
MP3130
MP3140
MP3142
MP3143
MP3210.0-7
MP3240.1
MP3240.2
MP3310
MP3310.0
MP3310.1
MP3411.0-7
July 2002
Function and input
Polarity of the nominal spindle speed
Input:
0: M03 positive, M04 negative
1: M03 negative, M04 positive
2: M03 and M04 positive
4: M03 and M04 negative
Counting direction of spindle position encoder output
signals
Input:
0: Positive counting direction with M03
1: Negative counting direction with M03
Line count of the spindle position encoder
Input:
100 to 9 999 [lines]
Mounting configuration of the spindle position encoder
Input:
0: Position encoder directly on the first spindle
1: Position encoder via transmission (ratio in
MP3450.x and MP3451.x); X30 pin 1: reference
pulse
2: Position encoder via transmission (ratio in
MP3450 and MP3451); X30 pin 1: reference
pulse release
3: Same as input value 1, except that the second
reference pulse is evaluated.
Analog nominal spindle voltage at rated speed for the
gear ranges 1 to 8
Input:
0 to 100,000 [V]
Digital spindle motor revolutions at rated speed for the
gear ranges 1 to 8
Input:
0 to 100.000 [1000 rpm]
Analog spindle: Minimum nominal value voltage
Input:
0 to 9.999 [V]
Digital spindle: Minimum motor speed
Input:
0 to 9.999 [1000 rpm]
Analog spindle: Spindle jog voltage for gear shifting
(M4009/M4010)
Input:
0 to 9.999 [V]
Digital spindle: Motor speed for gear shifting (M4009/
M4010)
Input:
0 to 9.999 [1000 rpm]
Limitation for spindle speed override
Input:
0 to 150 [%]
Upper limit
Lower limit
Ramp gradient of the spindle with M03 and M04 for
gear ranges 1 to 8
Input:
Analog axes: 0 to 1.999 [V/ms]
Digital axes: 0 to 1.999 [(1000 min/min) · ms]
Software