MP
MP3412
MP3412.0
MP3412.1
MP3412.2
MP3412.3
MP3415
MP3415.0
MP3415.1
MP3415.2
MP3415.3
MP3420
MP3430
MP3440.0-7
MP3450.0-7
MP3451.0-7
MP3510.0-7
MP3515.0-7
MP3520.0
MP3520.1
25 – 316
Function and input
Multiplication factor for MP3411.x
Input:
0.000 to 1.999
With M05
With oriented spindle stop
With tapping with floating tap holder
With rigid tapping
Overshoot behavior of the spindle with M03, M04 and M05
Input:
0 to 1000 [ms]
With M03, M04 and M05
For oriented spindle stop
With tapping
With rigid tapping
Spindle positioning window
Input:
0 to 360.0000 [°]
Deviation of the reference mark from the desired position
(spindle preset)
Input:
0 to 360 [°]
k
factor for spindle orientation for gear ranges 1 to 8
V
Input:
0.1 to 10 [(1000°/ min) /°]
Number of spindle position-encoder revolutions for gear
ranges 1 to 8
Input:
0 to 65,535
0: No transmission
Number of spindle revolutions for gear ranges 1 to 8
Input:
0 to 65,535
0: No transmission
Rated speed for the gear ranges 1 to 8
Input:
0 to 99 999.999 [rpm]
Maximum spindle speed for gear ranges 1 to 8
Input:
0 to 99 999.999 [rpm]
Speed activation through marker M4011
Input:
0 to 99 999.999 [rpm]
Spindle speed for oriented stop
Input:
0 to 99 999.999 [rpm]
Software
version and
behavior
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
PLC
RUN
HEIDENHAIN Service Manual iTNC 530