25.1.8 Configuration of the data interface

MP
MP5000
MP5020
MP5020.0
MP5020.1
MP5020.2
MP5030
MP5030.0
MP5030.1
MP5030.2
MP5040
July 2002
Function and input
Disable data interfaces
Input:
0: No interface disabled
1: RS-232-C/V.24 interface disabled
2: RS-422/V.11 interface disabled
Configuration of the data interface
Format:
%xxxxxxxx
Input:
Bit 0 –
0: 7 data bits
1: 8 data bits
Bit 1 -
0 = Any BCC character
1 = BCC not control character
Bit 2 -
0: Transmission stop by RTS not active
1: Active
Bit 3 -
0: Transmission stop by DC3 not active
1: Active
Bit 4 -
0: Character parity even
1: Odd
Bit 5 -
0: Character parity not desired
1: Desired
Bit 6 = 0, Bit 7 = 0: 1 stop bit
Bit 6 = 1, Bit 7 = 0: 2 stop bits
Bit 6 = 0, Bit 7 = 1: 1 stop bit
Bit 6 = 1, Bit 7 = 1: 1 stop bit
Operating mode EXT1
Operating mode EXT2
Operating mode EXT3 (PLC)
Data transfer protocol
Input:
0 = Standard data transfer protocol
1 = blockwise transfer
2 = without protocol (only for MP5030.2)
Operating mode EXT1
Operating mode EXT2
Operating mode EXT3 (PLC)
Data transfer rate in operating mode EXT3 (data transfer
through PLC)
Input:
0: 110 bps
1: 150 bps
2: 300 bps
3: 600 bps
4: 1200 bps
5: 2400 bps
6: 4800 bps
7: 9600 bps
8: 19200 bps
9: 38400 bps
10: 57600 bps
11: 115 200 bps
Software
version and
behavior
PLC
RUN
PLC
RUN
CN123
PLC
RUN
CN123
PLC
RUN
25 – 319