Error
Cause of error
number
3002
The code number 561320 is non-
functional because the servicing
mode for the spindle was not
enabled by the machine tool
manufacturer.
312
While defining the Contour Lines
cycle (TCH PROBE 7) you
programmed a height axis in the
starting point.
2698
Cyclic voltage monitoring could not
be carried out.
869
Memory is tested whenever the
control is switched on.
452
You programmed a mirror image
before the TCH PROBE 0 cycle
(ISO: G55) or before the digitizing
cycles.
248
During measurement of the stylus
center offset the spindle was not
rotated by 180 degrees.
388
You called a fixed cycle without first
switching on the spindle.
2655
The spindle motor is receiving
current, although its inverter was
switched off!
3199
During a mid-program startup, the
active gear range did not match the
gear range at the restore position.
During a mid-program startup, the
active spindle did not match the
spindle required at the restore
position.
2711
Checksum was not yet entered,
or it is incorrect.
2743
Checksum error due to faulty data.
170
In a LBL CALL (ISO: L 0,0) block of
a part program or in a jump
instruction (parametric calculation)
you attempted to program a jump
to the label 0.
Safe reduced rotational velocity
(SRG) was exceeded.
No standstill in safe controlled stop
(SBH) operating mode.
2879
The safe reduced speed SRG was
exceeded while the protective door
was open.
2886
Internal software error
2929
NE2 input incorrectly connected.
Software error
2928
NR2 input incorrectly connected.
Software error
225
You have programmed a thread
pitch of 0 in the Rigid Tapping cycle
or Tapping cycle.
Corrective action
Check MP560.
Inform your service agency.
Edit the part program.
Inform your service agency.
Wait until the message disappears,
or acknowledge the message
with CE.
Delete the Mirror Image cycle.
Rotate the spindle by 180 degrees.
Edit the part program.
Inform your service agency.
Restart the mid-program startup.
Before the mid-program startup,
activate the gear range and/or the
spindle that is needed at the
restore position.
If the error recurs, contact your
service agency.
Inform your service agency.
Inform your service agency.
Edit the part program.
Inform your service agency.
Inform your service agency.
Inform your service agency.
Check the software version.
Inform your service agency.
Check the wiring.
Check the software version.
Inform your service agency.
Check the wiring.
Check the software version.
Edit the part program.