Error message
C350 Axis module
not ready
C370 Angle error
motor encdr.
C380 Motor not
controllable
C3B0 Motor does
not rotate
CCU +5V iTNC
outside tolerance
CCU amplitude too
high %.2s
CCU amplitude too
small %.2s
July 2002
Error
Cause of error
number
No pulse release for the power
supply unit.
Uz too high.
5-V power supply too weak.
Inverter is not ready for operation.
Motor control board defective.
PWM cable defective.
Noise pulses.
Motor encoder defective.
Motor encoder cable is defective.
Drive control board defective.
Motor cables were crossed
(e.g. X with Y).
Motor encoder cables crossed.
Phases connected incorrectly to
motor.
Motor encoder cable is defective.
Incorrect entry in motor table
(rotation direction, no. pole pairs).
Motor defective.
Check the motor cabling.
Current or speed controller not
optimized (values too high).
Inverter is not ready for operation.
Disturbance on RDY input of PWM
output connector.
Motor jammed.
Inverter defective.
Motor defective.
Incorrect motor selected (MP2200).
Assignment of PWM outputs
entered incorrectly in MP120.
Assignment of PWM inputs
entered incorrectly in MP112.
Motor power cables crossed.
Motor encoder cables crossed.
Motor connection defective.
2688
The 5V power supply of the iTNC is
outside the permissible tolerance
range.
2720
The amplitude of the encoder signal
is too large or the signal for
contamination is active.
44
The amplitude of the encoder signal
is too small or the signal for
contamination is active.
Corrective action
Inform your service agency.
Check the control and cabling of
the pulse release.
Check Uz.
If the power supply is not
regenerative: Is the braking resistor
connected?
If the power supply is regenerative:
Is the energy recovery activated?
Check the grounding and shielding
of the cable.
Exchange the power module.
For P controls: Exchange the
interface card.
Exchange the motor drive control
board.
Inform your service agency.
Check the motor encoder and
leads.
Exchange drive control board.
Inform your service agency.
Check motor and motor cables.
Check the entry in the motor table.
Inform your service agency.
Check the inverter.
Check the motor and cabling.
Check the machine parameters.
Inform your service agency.
Check the amplitude of the
encoder signal.
Check the amplitude of the
encoder signal.
2 – 25