Error message
MCU command
unknown
ME: Tape end
ME: Incorrect
operating mode
ME: Cassette is
empty
ME: Cassette is
write-protected
ME: Cassette is
missing
Only one DEP block
permitted
Measuring touch
probe selected
%.2s measuring
system defective
Axis encoder
defective
Axis encoder:
amplitude too low
Axis encoder:
frequency too high
Encoder input %.2s 2911
Measuring cycle:
Length exceeds
max.
Measuring cycle:
Length below min.
Measuring cycle:
M114 not
permitted.
July 2002
Error
Cause of error
number
2869
Internal software error.
195
The cassette in the ME magnetic
tape unit has reached the end of the
tape.
192
The operating mode set at the ME
magnetic tape unit (transmit/
receive) does not match the
transmission direction set at the
TNC.
193
The cassette loaded in the ME
magnetic tape unit is empty.
191
The cassette loaded in the ME
magnetic tape unit is write-
protected.
190
No cassette was loaded in the ME
magnetic tape unit.
294
You programmed more than one
DEP block in the definition of a
contour or a contour train.
1170
You have attempted to start a
digitizing cycle for a triggering
probe, although a measuring probe
is defined in machine parameter
MP6200.
46
Contradiction apparent from
comparison of the absolute and
incremental positions.
Error on coded scales.
Amplitude error.
Signal frequency error
(edge separation).
Incorrect entry in MP112 or MP113
(speed encoder).
Internal software error.
2520
Probing cycle 425 or 427: The
measured length exceeds the max.
permissible value.
2521
Probing cycle 425 or 427: The
measured length is below the min.
permissible value.
2748
You attempted to run a measuring
cycle while M114 was active.
Corrective action
Inform your service agency.
Check the software version.
Turn the cassette over or insert
a new one.
Correct the transmission direction
(transmit/receive) set on the ME.
Insert the correct cassette.
Cancel the write-protection on the
cassette.
Insert a cassette into the ME.
Edit the part program.
Edit machine parameter MP6200.
Inform your service agency.
Glass scale tape contaminated or
damaged.
Scanning head contaminated or
defective.
Cable damaged.
Encoder input on iTNC defective.
Glass scale tape contaminated or
damaged.
Scanning head contaminated or
defective.
Cable damaged.
Encoder input on iTNC defective.
Glass scale tape contaminated or
damaged.
Scanning head contaminated or
defective.
Cable damaged.
Encoder input on iTNC defective.
Inform your service agency.
Check entry in MP112 / MP113.
Check software version.
Check the workpiece, and if
necessary the measuring log.
Check the workpiece, and if
necessary the measuring log.
Use M115 to cancel M114 before
running the measuring cycle.