Error message
Tmax of motor table
%.2s
TNC program block
not permitted until
contour is resolved
TNC operating
temp. exceeded
Tolerance
exceeded
Tolerance value too
great
No TOOL CALL
permitted with
M128
TOOL.T: LCUTS or
ANGLE missing!
TOOL.T: Enter
number of teeth
TOOL.T: Too many
tools
TS: Inadequate
consistency
Calibrate TT in tilted
plane
TT not parallel to
tool axis
Calibrate TT in
non-tilted plane
July 2002
Error
Cause of error
number
2903
Incorrect temperature entry in
motor table.
507
FK programming: Conventional
blocks may follow an FK block
only if the FK block led to a
complete resolution of the contour.
Exceptions:
RND block
CHF block
L block containing only motion in
the tool axis or auxiliary axis.
204
The temperature sensor in the
iTNC has detected an excessively
high temperature inside the control
housing.
3193
Cycle 440: The maximum
permissible tolerance for thermal
expansion was exceeded in one
axis.
1097
Geometry error message: The
tolerance value entered with M124
is greater than half the tolerance
value in M112.
2211
A TOOL CALL is not permitted with
M128 active.
1682
Cycle 22 needs informaion on the
tooth length and the plunge angle
of the active tool.
The data for LCUTS and ANGLE
are missing in the tool table.
The tool table is not active.
1193
Automatic tool measurement:
Number of teeth not entered into
tool table.
1075
More than 99 tools are defined in
the tool table.
2273
During multiple measurement
with the automatic probe cycle
the variance of the individual
measured values is greater than
the value defined in machine
parameter MP6171.
2824
You attempted to run a cycle for
tool measurement while the tilted-
plane function was active, although
the touch probe was not calibrated
in the tilted working plane.
2826
You attempted to run a cycle for
tool measurement although the
touch probe is not parallel to the
tool axis.
2825
You attempted to run a cycle for
tool measurement, although the
touch probe was last calibrated in
a tilted working plane.
Corrective action
Inform your service agency.
Check the motor table.
Resolve the FK contour completely.
Check for adequate heat transfer
in the electrical cabinet.
Increase permissible tolerance:
Change LTOL/RTOL of calibration
tool.
Allow machine to cool down.
Reduce tolerance value in M124.
Enter M129 to cancel M128 and
then run the TOOL CALL.
In the tool table, enter LCUTS
and ANGLE for the current tool.
Activate the tool table via machine
parameter 7260 or 7224.
Transfer number of teeth (CUT.)
into TOOL.T.
Delete some lines out of the tool
table so that no more than 99 tools
are stored.
Check whether the probe point and
the stylus are clean.
Expand the tolerance in machine
parameter MP6171.
Run the calibration cycle 30 while
the working plane is tilted.
Position the axes so that the touch
probe axis and the tool axis are
parallel.
Run the calibration cycle 30 when
the working plane is not tilted.
2 – 73