Error message
CYCL 211 not
permitted
CYCL CALL PAT
not permitted
CYCL DEF not
defined
CYCL DEF
incomplete
CYCL parameter
incorrect
File %.16s is
missing
File %.16s is
missing
File %s%s already
exists
File empty
File not found.
File not found in
OEM.SYS
File format has
changed
File name on data
medium assigned
Program name
already exists
Program name
already exists
File system error 1
File system error 2
File system error 3
July 2002
Error
Cause of error
number
2046
Cycle 211 cannot be run in the
CIRCULAR PATTERN or LINEAR
PATTERN cycles.
3189
You have used Cycle 12 (ISO: G39)
to declare a program containing
CYCL CALL PAT to be a cycle.
261
You have programmed a cycle call
without having first defined a fixed
cycle.
You attempted to call a cycle that
automatically becomes active upon
definition.
260
You deleted part of a cycle.
You have inserted other part-
program blocks within a cycle.
447
For digitizing cycles:
Probe point interval greater than
65 535 (with Q parameter)
Incorrect line-by-line digitizing axis
498
Error in compensation value
conversion: The *.COM file
selected in the *.CMA file does not
exist.
499
"PGM not found" error message
during Include in ASCII file.
2498
You have already used the entered
file name for another file type.
2225
You attempted to select a tool
material or a cutting material
although the corresponding table
has no entries.
2382
In your program you called a file or a
table that does not exist in your
TNC.
2222
You attempted to use a workpiece-
material table or a tool-material
table, although your machine
manufacturer has not made the
required entries in OEM.SYS.
1186
This error message will be
displayed when opening a binary
file (*.H,*.T...) if the binary format
has changed since the last output
version.
1035
The file name already exists on the
external data medium.
186
You attempted to create a file that
already exists.
944
This file name already exists.
1160
Incorrect cluster number in the
"get_cluster" routine, caused by a
software error.
1161
Incorrect cluster number in the
"put_cluster" routine, caused by a
software error.
1162
Incorrect cluster number in the
"next_cluster" routine, caused by a
software error.
Corrective action
Use another fixed cycle.
CYCL CALL PAT in connection
with cycle 12 (ISO: G39) is not
permitted.
Define the cycle call after definiton
of a fixed cycle.
Delete the cycle call.
Redefine complete cycle again.
Delete NC blocks within cycle.
Check the entries in the digitizing
cycle.
Load the file.
Load the file.
Select a new file name or delete
the existing file.
Enter the missing workpiece
material in the file MAT.TAB or the
missing cutting material in the file
CUT.TAB.
Enter the name of an existing table.
The OEM.SYS must be changed.
Contact your machine tool builder.
Delete the file.
Select with the YES/NO key
whether to overwrite the file.
Use another file name.
Select another file name.
Inform your service agency.
Inform your service agency.
Inform your service agency.