Reconverting data
Do not confirm error messages that may be displayed on the iTNC.
from ASCII to
Press the following key combination:
binary format
Copy sample files
With the COPY SAMPLE FILES soft key, the HEIDENHAIN standard tables for cutting data,
the tables for tilting-axis geometry, and the table of M-function macros can be copied into the
corresponding directories.
Tables already edited in a previous software version must have a different name or be stored
in another directory; otherwise they will be overwritten.
Restoring the
If necessary, read in previously moved files.
default settings
Recalibrate touch probes.
on the machine
Initialize swivel head again.
Contact the machine manufacturer for more information.
Initialize tool changer again.
Contact the machine manufacturer for more information.
July 2002
Select Programming and Editing operating mode.
Prepare iTNC for entry of code number.
Confirm.
Call submenu.
Call submenu.
Note: It is not necessary to enter the directory that is shown on the
iTNC screen.
The files on the hard disk are converted back into binary format.
During the conversion a progress window is displayed.
Exit the subordinate mode once conversion has been completed.
Note
A log for the conversion process is stored in the file TNC:\CVREPORT.A.
Caution
The three files with the endings _bin.zip, _heros.zip and _setup.zip required to update the
NC software are automatically stored in SYS:\zip\ ... by the iTNC.
Therefore, you should delete the directory (e.g. PLC:\SWUPDATE\ ...) into which you have
transferred the zip files from you laptop to the control to free the memory.
Enter the code number.