FA U LT I SO LAT I ON
Tests not l isted m ay either pass or fail
(don't cares).
To use table, start w ith f i rst line.
1. Test A l l passes
2.
Test A l l does not com p l ete self-tests
(test log is not d i s p l ayed)
3. FPP Fails
4. FFT Fails
5 . G l obal RAM Fails
6. Keyboard Status Test Fails
7. D FA I nterrupt F a i l s
8. D FA Unfi ltered C h a n
I nterrupt Fails
9. Source Test Fails,
Cal ibration Fai ls,
Front End Passes
1 0. C a l ibration Fails,
Front End Passes,
Source Test Passes
1 1 . Calibration Fails,
Front E nd Fails only on one
c hannel,
Source Test Passes
B.
Test A l l Table
U s e tab le 7-6 to h e l p dete r m i ne the fai l u re after ru n n i ng the Test A l l d i agnostic or any
i nd ivid ual self-tests. The tab le I ists the self-tests in the order the Test A l l d i agnostic executes
them. A pass message indicates the assemb l ies and subblocks tested are probably operati ng
correctly. The pass/f a i l messages are l isted on the vertical axi s of the tab le. T he assembl ies
and subblocks tested o r used by the self-tests are l isted on the horizontal axi s of the tab le.
(Refer to the i ntrodu ction of paragrap h 7-7 for the l ist of asse m b l ies not tested by Test A l l .)
There are two sym b o l s used i n tab le 7-6:
tab le, the assem bly or subblock is used in the test but is not a l i kely cause of the fai l u re .
When the sym bol "X" is used i n the tab le, the asse m b ly or s u b b lock is probably the cause
of the fai l u re. No symbol means the assem bly or s u bb l ock is not u sed i n the test.
7-20
Table
7-5
Test All Result
TEST ALL Results
Go to Paragraph
7-7, part B, "Test A l l Table"
7-7, part C,
"Test A l l Does Not Complete"
8-1 0 A7 F P P
8-1 3 A 9 F FT
8-1 1 A8, A1 7 G lobal RAM and
D isplay I nterface
8-1 5 A1 S Keyboard
7-8 Isolating Front E nd F a i l u res
7-8 I so l ati n g Front E n d Fail ures
7-9 Sou rce F a i l u res
8-1 7 A30 A nalog Sou rce
7-8, part C,
"AS, A6 D igital F i l ter C heck"
7-8 Isolating Front E n d F a i l u res
0
x.
and
When the sym bol
MOD E L 3562A
"0"
i s used i n the

Hide quick links: