RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
9.5.1.4.
Table of configuration parameters
To correctly display the parameter values, you need to load them from the low kit, using
the "Read from low kit" function.
To change the setting, press the CHANGE key and insert the value using the numeric keyboard.
Press ENTER key to confirm or BACK key to back forward.
After any changes to the parameter values, you need to load them in the low kit using
the "Write to low kit" function.
Parameter
Par 01
Default speed for Quick Start workout. [Km/h*10]
Default acceleration and deceleration for tread
Par 02
belt motor. [Km/h*100/sec]
Default zero reference position for tread-belt
Par 03
incline. [*2]
Par 04
PID proportional gain. [*100]
Par 05
PID Integral gain. [*100]
Par 06
Ramp Type
Par 07
Error status on DC motor encoder
Par 08
Serial communication timeout [10*msec]
Par 09
DC motor encoder error timeout. [msec]
Par 10
Par 11
FREE
Par 12
Driving roller diameter. [mm]
Par 13
Pulley ratio
n.m = Value not modifiable.
Press HOME to confirm and save, FORWARD or BACK to scroll the pages.
Description
Range
Default values
n.m.
8
n.m.
100
n.m.
0
n.m.
7
n.m.
150
n.m.
0
0 - 1
0
n.m.
0
0 - 255
15
-
0
n.m.
91
n.m.
200
0 - 1
0