General Specifications

SJ100DN DeviceNet Series inverters have the same electrical characteristics for driving
the motor as the standard SJ100 inverters. So, refer to the SJ100 instruction manual for
the electrical specifications tables and derating curves. The general specifications in this
section will be similar to the those for the standard SJ100 inverters, but they reflect the
differences given in "Comparison Summary, Standard vs. DeviceNet Series" on page 4.
The following table applies to all SJ100DN DeviceNet Series inverters.
Item
Protective housing *1
Control method
Output frequency range *2
Frequency accuracy
Frequency setting resolution
Volt./Freq. characteristic *3
Overload current rating
Acceleration/deceleration time
Input
Freq.
Operator panel Up and Down keys / Value settings
signal
setting
Network
FWD/
Operator panel Run/Stop (Forward/Reverse run change by command)
REV
External signal Forward run/stop, Reverse run/stop (on intelligent terminals)
Run
Network
Intelligent input
terminal
Output
Intelligent output
signal
terminal
Other functions
Protective function
General Specifications
IP20
Sine wave pulse-width modulation (PWM) control
0.5 to 360 Hz
Digital command: 0.01% of the maximum frequency
Digital: 0.1 Hz; DeviceNet: 0.01 Hz
V/f optionally variable, V/f control (constant torque, reduced
torque), sensorless vector control
150%, 60 seconds
0.1 to 3000 sec., (linear accel/decel), second accel/decel setting
available
DeviceNet polled I/O – continuous update of output frequency
Forward run/stop, Reverse run/stop
FW (forward run command), RV (reverse run command), CF1~CF4
(multi-stage speed setting), JG (jog command), 2CH (2-stage accel./
decel. command), FRS (free run stop command), EXT (external
trip), USP (startup function), SFT (soft lock), RS (reset), PTC
(thermal protection), DB (external DC braking command), SET (2nd
setting selection), STA (start, 3-wire interface), STP (stop, 3-wire
interface), F/R (FW/RV, 3-wire interface), DNT (DeviceNet select),
UP (remote control accel.), DWN (remote control decel.), OPE
(Force Operation from Digital Operator)
RUN (run status signal), FA1,2 (frequency arrival signal), OL
(overload advance notice signal), AL (alarm signal)
AVR function, curved accel/decel profile, upper and lower limiters,
16-stage speed profile, fine adjustment of start frequency, carrier
frequency change (0.5 to 16 kHz) frequency jump, gain and bias
setting, process jogging, electronic thermal level adjustment, retry
function, trip history monitor, 2nd setting selection, auto tuning, fan
ON/OFF selection
Over-current, over-voltage, under-voltage, overload, extreme high/
low temperature, CPU error, memory error, ground fault detection at
startup, internal communication error, electronic thermal, CT error,
DeviceNet comm. error
SJ100DN Inverter
7