4–50
Using Intelligent Output Terminals
Watchdog timer
C077 =xx.xx sec.
C076
Logic Output Function
The Logic Output Function uses the inverter's built-in logic feature. You can select any
two of the other nine intelligent output options for internal inputs (use C141 and C142).
Then, use C143 to configure the logic function to apply the logical AND, OR, or XOR
(exclusive OR) operator as desired to the two inputs.
Intelligent outputs used
as internal inputs:
RUN, FA1, FA2, OL, OD,
AL, Dc, FBV, NDc
RUN, FA1, FA2, OL, OD,
AL, Dc, FBV, NDc
A Input
(C141 select)
0
0
1
1
Master
Slave
[NDc]
Alarm
=00 or 01
Input States
B Input
(C142 select)
0
1
0
1
C141
Input A
C142
Input B
[LOG] Output State
AND
OR
(C143=00)
(C143=01)
0
0
0
1
0
1
1
1
Time-out
C143
Logic function
[LOG]
AND, OR, XOR
XOR
(C143=02)
0
1
1
0
t