“H” Group: Motor Constants Functions - Hitachi X200 Series Instruction Manual

X200 series inverter
Hide thumbs Also See for X200 Series:
Table of Contents

Advertisement

"H" Group: Motor Constants Functions
The "H" Group parameters configure the
inverter for the motor characteristics. You must
manually set H003 and H004 values to match
the motor. Parameter H006 is factory-set. If you
want to reset the parameters to the factory
default
settings,
"Restoring Factory Default Settings" on page 6-
8. Use A044 to select the torque control
algorithm as shown in the diagram.
Func.
Name /
Code
SRW Display
H003
Motor capacity
AUX K
H203
Motor capacity, 2nd motor
2AUXK
H004
Motor poles setting
AUX P
H204
Motor poles setting, 2nd
motor
2AUXP
H006
Motor stabilization
constant
AUX KCD
H206
Motor stabilization
constant, 2nd motor
2AUXKCD
use
the
procedure
"H" Function
Ten selections:
0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.7/
5.5/7.5
0.4 kW
Ten selections:
0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.7/
5.5/7.5
0.4 kW
Four selections:
2 / 4 / 6 / 8
4p
Four selections:
2 / 4 / 6 / 8
4p
Motor constant (factory set),
range is 0 to 255
100
Motor constant (factory set),
range is 0 to 255
100
Inverter Torque Control Algorithms
V/f control,
constant torque
in
V/f control,
variable torque
Description
3 65
3 65
A044
00
Output
01
Run
Defaults
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
Specified by
kW
the capacity
of each
inverter
kW
model
4
4
poles
4
4
poles
100
100
100
100