Assigning a Function to a Memory
Recall Button in the Utility/Shotbox
Control Block
1
In the Panel >Prefs/Utility menu, press [Utility
Module Assign].
The Utility Module Assign menu appears. The status
area shows the settings in the utility/shotbox control

block.

2
Using any of the following methods, select the button
to be assigned.
• Press directly on the list.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knobs.
Knob Parameter Adjustment
1
Bank
2
Button No
3
In the <Action> group, select the function you want to
assign.
Menu Shortcut: Assign a frequently used menu to be
recalled (menu shortcut).
Utility Command: Assign a function on/off or similar
operation (utility command).
Macro Recall: Assign a macro register recall.
Shotbox Recall: Assign a shotbox register recall.
4
Depending on the selection in step 3, make the
following settings.
When Menu Shortcut is selected: For the subsequent
operations, see "Assigning a menu shortcut to a
memory recall button" (page 191).
When Utility Command is selected: A list of
commands appears on the right of the status area;
List of utility commands and memory recall button status
The following table shows the utility commands that can
be assigned to memory recall buttons.
a)
Command name
SWR Remote1 Enbl
|
SWR Remote4 Enbl
DME1 Editor Port Enbl
DME2 Editor Port Enbl
188
Setting Button Assignments (Prefs/Utility Menu)
Setting values
Bank selection
1 to 4
Control block
1 to 24
button selection
Function
Switcher Remote 1 enabled/disabled
|
Switcher Remote 4 enabled/disabled
DME1 editor port enabled/disabled
DME2 editor port enabled/disabled
using any of the following methods, select the
command you want to assign.
• Press directly on the list.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
3
Command Utility command
selection
a)
4
GPI No
GPI port number
a) When the Command parameter is set to Sw'er GPI Test Fire, Panel
GPI Test Fire, or DCU GPI Test Fire
When Macro Recall is selected: Turn the knob to
select the macro register you want to assign.
Knob Parameter Adjustment
3
Macro
Macro register
selection
When Shotbox Recall is selected: Turn the knob to
select the shotbox register you want to assign.
Knob Parameter Adjustment
3
Shotbox
Shotbox register
selection
5
Press [Action Set].
This assigns the selected action, which is reflected in
the status area.
In the utility/shotbox control block, the assigned
button lights orange.
If a shotbox register was assigned, the register name
appears.
To cancel an assignment
After selecting the relevant button, press [Clear].
To display register names in the Utility Command
column
If in step 3 you select [Macro Recall] or [Shotbox Recall],
press [Reg Name Display] to select whether or not register
names appear in the Utility Command column.
Button status
Lit green
Enabled
Enabled
Enabled
Setting values
1 to maximum
value
1 to maximum
value
Setting values
1 to 250
Setting values
1 to 99
Lit orange
Disabled
Disabled
Disabled