[USER 1] to [USER 8]: These select the User regions.
[DME 1] to [DME 8]: These select the DME
channels.
[RTR]: This selects the Router region.
[ALL]: This selects all regions.
[MASTR]: This selects a master snapshot.
Notes
The regions that can be selected simultaneously are
those assigned to the region selection buttons and
memory recall section (see page 165).
It is not possible to select [MASTR] and other regions
simultaneously. If selected simultaneously, the master
snapshot takes precedence.
The first pressed button lights green as the reference
region. Subsequently pressed buttons turn amber for
the region select buttons and yellow for the memory
recall section buttons.
Pressing one of the amber or yellow buttons, while
holding down [SNAPSHOT], turns the button green to
indicate its corresponding region as the new reference
region.
For details of the precedence order for becoming the
reference region, see "Reference region" (page 29).
The display shows the name of the reference region
and the number of the register previously recalled for
that region.
3
Select the bank for recall.
See step 4 (page 74) in "Saving a snapshot in the
Multifunction Flexi Pad control block."
4
To add a temporary attribute (see page 68), press the
[EDIT ENBL] button to switch to editing mode, then
press the [TEMP ATTR] button; you can now select
the temporary attribute with the following buttons.
[EFF DISS] button: Effect dissolve.
[DUR xxx] button: Effect dissolve duration. The
current setting is shown by "xxx."
[AUTO TRNS] button: Auto transition.
[XHLD xxx] button: Bus cross-point hold. The
affected bus is shown by "xxx."
For details of the operation of mode of the [XPT
HOLD] buttons, see "Selecting the Bank to Make the
Settings" (page 217).
Notes
Adding a temporary attribute does not affect the
attribute settings saved in registers.
76
Snapshot Operations in the Multifunction Flexi Pad Control Block
To add a temporary attribute with the cross-point
control block buttons, press the following buttons,
turning them on.
Temporary attribute to
be added
A/B bus cross-point hold
Key cross-point hold
Key disable
a) When setup setting is Xpt Hold mode
b) When setup setting is Key Disable mode
Notes
This setting is maintained until the next time the [XPT
HOLD] button is pressed.
5
Press the button in the memory recall section which
shows the desired register name.
The button you pressed lights yellow, and this recalls
the snapshot.
The alphanumeric display shows the selected register
number.
To cancel a snapshot recall operation
Press the [UNDO] button.
To enter the number of the register to be recalled
using the numeric keypad
After step 1 above, press the [10 KEY] button in the
memory recall section. This switches the memory recall
section to the numeric keypad input mode, and after
pressing the [RCLL] button, lighting it yellow, you can
enter the desired register number from the numeric
keypad. Confirm the displayed number by pressing the
[ENTR] button.
Deleting a snapshot in the Multifunction
Flexi Pad control block
As an example, to delete a snapshot on the M/E-1 bank,
use the following procedure.
1
In the Multifunction Flexi Pad control block, press the
[SNAPSHOT] button, press region selection button to
select [M/E 1] only.
This assigns the Multifunction Flexi Pad control block
to snapshot operations.
The alphanumeric display shows the last recalled
register number on the corresponding bank.
2
Select the bank for the register containing the snapshot
you want to delete.
Button to press
[XPT HOLD] button in
background A/B bus
Key bus [XPT HOLD]
a)
button
Key bus [XPT HOLD]
b)
button