Knob Parameter Adjustment
1
Address
Destination
address
2
Level
Destination level
6
When setting the tally type, set the following
parameter.
Knob Parameter Adjustment
3
Type
Tally type
a) 1:R1, 2:G1, 3:R2, 4:G2, 5:R3, 6:G3, 7:R4, 8:G4, 9:R5, 10:G5, 11:R6,
12:G6, 13:R7, 14:G7, 15:R8, and 16:G8 (R is an abbreviation of
"Red Tally," and G of "Green Tally").
7
Press [Execute].
This makes the parallel tally settings, in accordance
with the settings in steps 1 to 6.

Deleting Parallel Tally Settings

1
In the Router/Tally >Parallel Tally menu, using any of
the following methods, select the parallel tally whose
settings you want to delete.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knobs.
Knob Parameter Adjustment
1
Slot No
Parallel tally slot
number
2
Port No
Parallel tally port
number
2
Press [Clear].
Setting values
Serial Tally Settings
1 to 1024
(Serial Tally Menu)
1 to 8
To make serial tally settings, display the Router/Tally
>Serial Tally menu.
Make the serial tally settings, including tally type and
source address for each serial tally port.
Setting values
a)
1 to 16
To display the Serial Tally menu
In the Engineering Setup menu, select VF6 'Router/Tally'
and HF7 'Serial Tally.'
The serial tally settings appear in the status area.
Setting or Changing the Serial Tally
Settings
1
In the <Serial Tally Port> group of the Router/Tally
>Serial Tally menu, select the port to which the setting
applies.
2
In the <Tally Group> group, select the tally group.
3
In the <Tally Type> group, press the tally types to
select. You can select up to four.
Notes
The selectable tally types depend on the settings in
Setting values
step 2.
2 to 6
4
In the <Tally Data Size> group, press one of the
1 to 54
following to select the data size.
128 Bit: 128 bits
256 Bit: 256 bits
Making the Serial Tally Source
Address Settings
To set the serial tally source address for each port, use the
following procedure.
1
In the Router/Tally >Serial Tally menu, press [Source
Assign].
The Source Assign menu appears.
In the status area, the tally types and source address set
for the serial tally port appear.
2
In the <Serial Tally Port> group, select the port to
which the setting applies.

Serial Tally Settings (Serial Tally Menu)