Sony MVS-8000X User Manual page 193

Systems, with ccp-8000 series center control panel
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

(Falling Edge): Apply the trigger on a falling
edge of an input pulse.
(Any Edge): Apply the trigger on a change in
the polarity of the input signal.
(Level): Carry out the specified operation when
the input is low or high.
No Operation: Apply no trigger on an input pulse.
4
In the <Target> group, select the action block.
M/E-1, M/E-2, M/E-3, M/E-4, M/E-5, P/P: Set the
action for one of the banks.
Common/Setup: Set an action for something other
than the above, or a setup action.
5
Using any of the following methods, select the action
to be set.
• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knobs.
Knob Parameter Adjustment
2
Action
Action selection
4
Aux Bus
AUX bus
No
selection
5
Reg No
Register number
5
Src No
Source signal
selection
5
No
User preference
button selection
a) As for the setting values, see "Selectable actions for various trigger
types" (page 193).
b) When knob 2 selection is "Aux ? O'ride Src ??"
c) When knob 2 selection is "Key Snapshot"
d) When knob 2 selection is "Snapshot" or "Shotbox"
e) When knob 2 selection is "Macro"
f) When knob 2 selection is "Effect"
g) When knob 2 selection is "Prefs Button?"
h) The following values apply to the MVS-8000X.
For primary inputs: 1 to 144
For premium inputs: 145 to 164 ((PREM1) to (PREM20) indicated
after the number)
For format converter dedicated inputs: 165 to 180 ((FC1) to (FC16)
indicated after the number)
i) The values from 1 to 80 apply to the MVS-7000X.
6
Press [Action Set] to confirm the action selection.
The selected setting appears in the status area.
Selectable actions for various trigger types
• When the trigger type is other than "Level"
In M/E-x, the x is the M/E bank number (1 to 5); in
DSKx the x is the DSK number (1 to 8); in Keyx the x is
the key number (1 to 8).
When Target is M/E-x: Cut, Auto Trans, Keyx Cut,
Keyx Auto Trans, Keyx SS ? Recall
When Target is P/P: Cut, Auto Trans, DSKx Cut, DSKx
Auto Trans, DSKx SS ? Recall, FTB Auto Trans, FTB
Cut
When Target is Common/Setup: Master SS ? Recall,
Master Effect ? Recall, SS ? Recall, Effect ? Recall,
Effect ? Recall & Run, KF Run, KF Stop, KF Rewind,
FM Src1 Frame Freeze, FM Src1 Field Freeze, FM
Src1 Freeze Off, FM Src2 Frame Freeze, FM Src2
Field Freeze, FM Src2 Freeze Off, FM Src1 Clip
Record, FM Src1 Clip Stop, FM Src2 Clip Record, FM
Src2 Clip Stop, FM1 to FM8 Clip Cueup, FM1 to FM8
Clip Play, FM1 to FM8 Clip Stop, Shotbox ? Recall,
Macro Take, Prefs Button?, Macro ? Recall, No
Action
• When the trigger type is only "Rising Edge" or
"Falling Edge"
Aux? O'ride Src ??
• When the trigger type is "Level"
When Target is M/E-1, M/E-2, M/E-3, M/E-4, M/E-5, or
P/P: No Action
When Target is Common/Setup: System Format (overall
Setting values
system settings), Aspect (overall system settings),
1 to maximum
Level Enable, Panel Status, No Action
a)
value
b)
1 to 48
Notes
c)
1 to 4
• "Level Enable" is a function that determines whether
d)
1 to 99
GPI inputs are enabled ("Enable") or disabled
e)
1 to 250
("Disable") for the "Aspect" and "System Format"
f)
1 to 399
actions that can be used when the trigger type is Level.
1 to maximum
When Level Enable is used, if the input is "Disable" then
b) h) i)
value
it is not possible to switch "Aspect" or "System Format"
g)
1 to 16
by GPI input.
If a GPI to switch "Aspect" or "System Format" occurs
when powering the system off, the action triggered by
the GPI may start immediately before the power goes off
and the power may go off before the action is completed.
This may corrupt the setup settings. It is therefore
recommended to use Level Enable to avoid such a
situation.
• As for "Aux ? O'ride Src ??," when "Rising Edge" is
selected, on a rising edge the set AUX bus input is used.
On a falling edge, the original state of the cross-point is
restored. If the GPI trigger is applied repeatedly at short
intervals (0.5 second or less), the cross-point switching
may not be carried out correctly. In this case, apply the
GPI trigger again.
• If "System Format" is selected for "Action" when the
format converter is used on the switcher, you can set the
conversion format of the format converter for "FC Input
1-4," "FC Input 5-8," "FC Input 9-12" (MVS-8000X
only), "FC Input 13-16" (MVS-8000X only), "FC
Output 1-2," and "FC Output 3-4."
• In Dual Simul mode, you can select the target switcher
for the panel status display using "Panel Status"
(H=SWR1, L=SWR2).