Advertisement

settings in this list will be saved as keyframe point
data. The right list is for selecting the action.
2
Select the P-Bus device for which you want to set an
action, by using any of the following methods to
specify the device ID.
• Press directly on the list on the left of the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
ID
Device number
3
Using either of the following methods, select the
action.
• Press directly on the list on the right of the status
area.
• Turn the knob.
Knob Parameter Adjustment
2
Action No
Action
a) 1: Off (no specification)
2: Store
3: Recall
4: Trigger
4
If in step 3 you selected 2 (Store), 3 (Recall), or 4
(Trigger), turn knob 3 to select the register number or
trigger number.
The indication for knob 3 changes to reflect the
selection of Store, Recall, or Trigger.
Knob Parameter Adjustment
3
Store No
Register number
for Store
3
Recall No
Register number
for Recall
3
Trigger No Trigger number
The setting is reflected in the list on the right of the
status area.
5
Press [Set].
For the device selected in the list on the left of the
status area, this sets the action specified in step 4.
Repeat steps 2 to 5 as required for other devices.
Testing an action command
To produce a test output of the action command, press
[Test Fire].
The action command is output from the 9-pin serial port of
the DCU according to the setting in the list on the left of
the status area.
Clearing an action setting
To clear the setting for separate devices
1
In the list on the left of the status area, select the device
for which you want to clear the action setting.
2
In the list on the right, select "Off."
3
Press [Set].
To clear the action settings for all devices in a
Setting values
single operation
Press [All Off].
0 to 23
Setting the action for a rewind operation
On the P-Bus timeline, when the [REWIND] button in the
keyframe control block is pressed the action set for the first
keyframe is not executed; when the [RUN] button is
pressed, then the first keyframe action is executed.
To execute an action when the [REWIND] button is
Setting values
pressed, it is necessary to set this action (Rewind Action).
a)
1 to 4
To carry out this setting, in the Device >P-Bus Timeline
menu, press [Rewind Action] to recall the Rewind Action
menu. In this setting screen, use the same setting method
as in the screen for setting an action on the P-Bus timeline.
Alternatively, you can select the reverse arrangement,
whereby when the [REWIND] button is pressed, this
executes the action set for the first keyframe, and when the
[RUN] button is pressed the first keyframe action is not
executed. In this case, the Rewind Action setting is still
valid.
For details, see "Setting the First Keyframe When a
Setting values
Rewind is Executed" (page 198).
1 to 250
Carrying out a Direct Store
1 to 250
You can carry out a Learn with the register number
specified for the device selected in the menu.
0 to 15
1
Using any of the following methods, select the device.
• Press directly on the list on the left of the status area.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Setting
1
2
In the Device >P-Bus Timeline menu, press [Direct
Store].
The numeric keypad window appears.
ID
Device ID
Control of P-Bus Devices
Setting values
0 to 23
13