Selecting the State After
Powering On (Start Up
Menu)
Set the initial state of the devices when the system is
powered on.
For each device, you can select Resume mode or Custom
mode.
Resume mode
This resumes the setting state at the previous power-off
operation. This setting is only available for the switcher
processor and control panel.
Custom mode
This uses the settings saved in non-volatile memory or
ROM within the device.
In this mode, there are Setup and Initial Status settings
which can be set separately.
• Setup mode: Select the setup state to be used after
powering on from the following.
User: Start up using the user data previously saved with
[Setup Define].
Factory: Start up with the factory default settings.
• Initial status mode: Select the state of each device after
powering on (excluding the settings to which "setup"
applies).
User: Start up using the user data previously saved with
[Initial Status Define].
Factory: Start up with the factory default settings.
For details of saving and recalling setup data, see "Saving
and Recalling Setup Data" (page 148) and the appendix
"Data Saved by [Setup Define] and [Initial Status
Define]" (page 272).
Autoload function
Switch on or off the function to automatically load
predetermined register data or frame memory image data
at power on. Set the data to be read in the File menu.
148

Selecting the State After Powering On (Start Up Menu)

Saving and Recalling Setup Data

Hard disk / memory card
User setup data
Load
File menu:
[Load]
Current setup data
(If in Resume mode, settings data is saved.)
Store
In Custom mode,
Setup
power on or reset
menu:
[Setup
Define]
Non-volatile memory
User setup data
Concept of saving and recalling setup data
Updating the switcher or control panel setup data saves the
updated setup data in RAM in each device.
• In Resume mode (see page 148), even if devices are reset
or powered off, the data is preserved in RAM, and
recalled when the power is turned back on.
Notes
The Resume mode cannot be used for DMEs and DCUs.
• In Custom mode (see page 148), the user-defined
settings (user setup data) saved in non-volatile memory
or factory default setup data held in ROM in each device
is recalled when a reset is made or the power is turned
back on (see page 149).
Note that the setup data in RAM can also be saved to the
control panel hard disk or memory card.
To set the initial state at start-up, use the System >Start Up
menu.
Notes
It is not possible to set the DCU state at start-up, but its
settings can be saved in the control panel.
To display the Start Up menu
In the Engineering Setup menu, select VF1 'System' and
HF4 'Start Up.'
The status area shows the current start-up mode settings of
each device.
Save
File menu:
[Save]
RAM
Initialize
Setup menu:
[All Clear]
ROM
Factory default setup data