Control Panel Setup
(Panel)
Overall Control Panel
Settings (Config Menu)
To carry out the overall control panel settings, use the
Panel >Config menu.
To display the Config menu
In the Engineering Setup menu, select VF2 'Panel' and
HF1 'Config.'
The status area shows the location numbers of the M/E and
PGM/PST banks, the allocated bank names, and whether
or not operation is enabled.

Panel Setup

In panel setup, you carry out settings particular to the
control panel.
You can make the following settings.
Panel settings (Config)
• M/E Assign: Set the logical configuration of the M/E
and PGM/PST banks.
• M/E Operation: For each of the M/E and PGM/PST
banks, make operations possible, not possible, or
disabled (Enable/Disable/Inhibit).
• Dual M/E Assign: Using two M/E banks, assign the
shift and non-shift button rows of a single M/E bank.
• Dual M/E Xpt Swap: When a setting has been made for
Dual M/E Assign, swap the shift and non-shift button
rows.
• DSK Fader Assign: Carry out fader function
assignment and key delegation for the key delegation
buttons, in each of the maximum of four downstream
key control blocks.
• External Bus Link: Make link settings relating internal
switcher buses to routing switcher destinations.
• Key Trans Link: Select whether or not to link
transitions between keyers, and if so which keyer to link
Chapter
to. You can set the links between keyers for each M/E
bank separately.
• Joystick/Trackball User Setting: When a trackball
module and a joystick module are both connected as
device control blocks, select which is used as the
reference. Also select whether key wipe positioning
applies to keys 1 to 8, or to keys 1 to 4.
• 10 Key Region Assign: Assign any regions to the region
selection buttons in the numeric keypad control block.
Also used for setting the regions included in the selection
when the [ALL] button is pressed.
• Program Button: Make assignments for buttons of
some control blocks such as assigning the buttons in a
transition control block for controlling a VTR and
assigning the Flexi Pad control block to macro
operation.
• Compact Key Module Assign: You can select which
keys can be operated with an independent key transition
control block (simple type).
• M/E Operation Inhibit: For each M/E or PGM/PST
bank, enable or inhibit utility 2 bus-related and key-
related operations.
• Joystick/Trackball Module: Enable or inhibit DME
channel selection operations from the device control
block (trackball) or device control block (joystick).
Interchanging the Bank Order or
Disabling Operation
1
In the Panel >Config menu, select the Bank you want
to set, using any of the following methods.
• Press directly on the status area display.
• Press the arrow keys to scroll the reverse video
cursor.
• Turn the knob.
Knob Parameter Adjustment
1
Bank
Select the
position of the
bank you want to
set

Overall Control Panel Settings (Config Menu)

19
Setting values
1 to 7